Threat Alert Escalation

DEFENDER

The AIMS® platform employs acoustic detection, emergency activation stations or panic buttons designed to activate a unique facility protection system. AIMS® provides three alert levels (Yellow, Blue, and Red) that escalate independently based on the situational severity. The automatic design features eliminate false positives, human error, and transitions to Red Alert upon any detection of gunshots. The AIMS® platform integrates with existing systems and components for maximum cost effectiveness. AIMS® is offered in 4 variations to accommodate facility needs and client budgets. Each offering builds on the capabilities of the system.

DEFCON LEVEL ONE

ACTIVE ASSAILANT

Activation Method
Push Button facility wide. Automated Detection Device. Remote App

Type of Events
Any active assailant event that is ongoing. To include: any active violent event

Upon active assailant event any occupant may activate any number of activation stations through-out the facility. Administrative personnel may also activate remotely from the administrative or command consoles.

System Components Engaged

Facility wide automatic immediate lockdown of all saferoom doors. Automated notification of an Active Assailant event to response force(s). Facility wide alarm of the event. Customized voice commands to occupants in saferooms. Camera surveillance of the active zone to the Command Console and responders. Optional pre-alert to disorientation medium device(s). Red LED Light activation on all light tree devices.

DEFCON LEVEL TWO

IMMINENT THREAT

Activation Method
Administrative console. Remote App.

Type of Events
Actionable intelligence indicating a serious threat of violent event.

Upon actionable intelligence information of an imminent threat, this level of protection may be activated by administrative permission from the admin console or remotely.

System Components Engaged

Facility wide automatic immediate lockdown of all saferooms doors. Facility wide camera surveillance. Facility wide voice command notification of a possible imminent threat. Blue LED activation of all light trees.

DEFCON LEVEL THREE

CAUTION

Activation Method
Administrative console. Remote App.

Type of Events
Information that may require a higher level of situational awareness by facility occupants.

Upon an administrative decision to issue a caution notification to all occupants. This level may be activated by administrative permission from the admin console or remotely.

System Components Engaged

Amber LED activation of all LED light trees.